Home Company Info Product Catalog Applications Links Engineering Services NIR Thin Bed Microwave Support Feedback History Contact Us Copy of HK Instrument Systems, Microwave Moisture, NIR, Radiometric Color

 

 

 

HK1   HK2                                      

        OPERATING TEMPERATURE                (AMBIENT) 32 TO 140 DEGREES F

        POWER REQUIREMENTS                     110 VAC OR 220 VAC OUTPUTS       

        OUTPUTS                                       (HK2) (1) 4-20 mA CURRENT OUTPUT

                                                                        (1) RS – 232 SERIAL OUTPUT

                                                               (HK1) (2) 4-20 Ma CURRENT OUTPUTS

                                                                        (2) RS-232 SERIAL OUTPUTS

        INPUTS                                           (HK2) (1) NTC TEMPERATURE SENSOR

                                                               (HK1) (1) RTD TEMPERATURE SENSOR

                                                                        (2) 4-20 MA CURRENT INPUTS

        ENCLOSURE                                            IP65, NEMA 4 EQUIVALENT

 

 

 

                           MICROWAVE INSERTION SENSORS

 

 

         MATERIAL OF MANUFACTURE             STAINLESS STEEL WITH SMALL

                                                                          POLY PROPYLENE CAPS ON THE END

         OPERATING TEMPERATURE                  (MAX) 40 TO 300 DEGREES F (CONTINUOUS)

         CLEANING TEMPERATURE                    (MAX) 400 DEGREES F (NON-CONTINUOUS)

 

 

                  MICROWAVE NON-INSERTION SENSORS (3A AVAILABLE)

 

 

         MATERIAL OF MANUFACTURE             STAINLESS STEEL WITH EPOXY WINDOW

         OPERATING TEMPERATURE                 45 TO 240 DEGREES F

  

 

                                            COAXIAL CABLES

 

 

         LENGTH                                             MAXIMUM 6.0 FEET

                                                                                        MINIMUM 2.0 FEET

         OPERATING TEMPERATURE              40 TO 140 DEGREES F

         TEMPERATURE VARIATION               MINIMIZE TEMPERATURE

                                                                   VARIATIONS  TO THE

                                                                   CABLE IF POSSIBLE

  

 

                                     VESSEL AND PIPE SIZES

 

 

         PIPE DIAMETER                                     MAXIMUM NONE

                                                                       MINIMUM 1-1/2 INCH

         VESSEL DIAMETER                                MAXIMUM NONE

                                                                       MINIMUM 1-1/2 INCH

   

 

                         PROCESS MATERIAL SPECIFICATIONS

 

 

         LIQUIDS/BULK MATERIALS                   MAXIMUM CONDUCTIVITY = 20,000 uS

                                                                                 

for requests outside of North America please fax to 412-291-0245 or e-mail to cferrin@hkinstruments.com

 

 

APPLICATION DATA SHEET (Microwave)

 

    Date:

 

    Company:          Contact:

 

    Phone #:             Fax #:   

 

    Address:   E-Mail:

 

    City: State: Zip:   Request for quote  Yes

 

    _____________________________________________________________________________

 

    Check appropriate configuration and Units of Measure

 

    Is the material to be measured a:    Liquid    or a Bulk Material

 

    Select from the following:    Vessel  Pipe  Belt

 

    What is the size of the Vessel/Pipe/Belt:     in.  mm.

 

    Select Units of Measure:  %Concentration   oBrix   %H2O   Other

   

    What is the Conductivity Range of the Process Stream?   Min  Max mS.

 

     What is the Pressure Range?  Min  Max PSIG

 

    Is the pipe always full?  Yes No            Is there air in the product?  Yes No

   

     What is the Application?

 

    Describe Product or Products

 

   

 

    Process Temp Range:  Min oF  oC    Max

 

    What is the Measuring Range?   Min    Max

 

    What are your accuracy requirements?   +/-

 

    Notes:

 

   

 

    Can the customer supply HK Instruments with samples to test?   Yes No

 

    From:

 

    Name:

 

    Date:   Phone:   Fax: